If you have any feedback on how we can make our new website better please do contact us. We would like to hear from you. 

STRUCTURED CABLING

Structured cabling
is building or campus telecommunications cabling infrastructure that consists of a number of standardized smaller elements (hence structured) called subsystems.

Structured cabling falls into five subsystems:

1.

Demarcation point is the point where the telephone company network ends and connects with the on-premises wiring at the customer premises.

2.

Equipment or Telecommunications Rooms house equipment and wiring consolidation points that serve the users inside the building or campus.

3.

Vertical or Riser Cabling connects between the equipment/telecommunications rooms, so named because the rooms are typically on different floors.

4.

Horizontal wiring can be IW (inside wiring) or Plenum Cabling and connects telecommunications rooms to individual outlets or work areas on the floor, usually through the conduits or ceiling spaces of each floor.

5.

Work-Area Components connect end-user equipment to outlets of the horizontal cabling system.

Structured cabling design and installation is governed by a set of standards that specify wiring data centres, offices, and apartment buildings for data or voice communications using various kinds of cable, most commonly category 5e (CAT-5e), category 6 (CAT-6), and fibre optic cabling and modular connectors. These standards define how to lay the cabling in various topologies in order to meet the needs of the customer, typically using a central patch panel (which is normally 19 inch rack-mounted), from where each modular connection can be used as needed. Each outlet is then patched into a network switch (normally also rack-mounted) for network use or into an IP or PBX (private branch exchange) telephone system patch panel.

Lines patched as data ports into a network switch require simple straight-through patch cables at each end to connect a computer. Voice patches to PBXs require an adapter at the remote end to translate the configuration on 8P8C modular connectors into the local standard telephone wall socket. No adapter is needed as the 6P2C and 6P4C plugs most commonly used with RJ11 (6P4C) and RJ12 (6P6C) telephone connections are physically and electrically compatible with the larger RJ45 (8P8C) socket.

It is common to colour code patch panel cables to identify the type of connection, though structured cabling standards do not require it except in the demarcation wall field.

Cabling standards demand that all eight conductors in Cat5e/6/6a/7/7a cable are connected, resisting the temptation to 'double-up' or use one cable for both voice and data. IP phone systems, however, can run the telephone and the computer on the same wires.

 
 